CONNECTING EXPERTISE - BUILDING SOLUTIONS.

All Categories

Home Product Automatic Hospital Door Radiation-Proof Lead Plate Door

OUTUS Lead-Lined Radiation Shielding Door – 1–10mm Pb CT & DR Room

1. Customisable lead lining: 1mm / 2mm / 3mm / 4mm / 5mm / 8mm / 10mm – specify X-ray voltage

2. Lead thickness calculator provided: input kV + room dimensions → recommended Pb thickness

3. 3rd-party attenuation test report included with every order – meets regulatory submission requirements

4. Manual break-out on power failure: door can be pushed open from inside in emergency

5. CE certified | Compatible with automatic operator (motorised) or manual pull-bar models

  • Products
  • Technical Data

Product description

1. High-quality lead plate filling, customizable lead equivalent 0.5-5mmPb, efficiently shield X/γ rays, protection effect meets industry standards

2. Translational sliding opening design, manual/electric dual modes optional, precise and smooth track, no jitter during opening and closing

3. Sturdy steel/aluminum alloy frame, stable and impact-resistant door structure, suitable for medical/industrial heavy-duty protection scenarios

4. Special radiation-proof sealing strips, full-circumference sealing design, completely prevent radiation leakage, more rigorous protection

5. Integrated soundproof and sealing technology, balancing radiation protection with sound and dust proof, optimizing the scene use environment

6. Customizable size/lead equivalent, suitable for different radiation dose scenarios such as hospitals/laboratories/industrial flaw detection

7. Sliding type does not occupy space, suitable for installation in narrow scenarios such as computer rooms and radiology departments, high space utilization

8. Durable accessories, wear-resistant sliding pulleys/tracks, less prone to failure after long-term use, low maintenance cost

9. Easy installation, complete supporting hardware, can be directly connected to existing walls, suitable for various building structures

10. Anti-corrosion spraying/stainless steel panel optional for surface, scratch-resistant, wear-resistant and easy to clean, suitable for medical sterile environment

11. Electric version supports intelligent linkage, can be connected to radiation equipment, close door when starting up and open when shutting down, more intelligent protection

12. Comply with national radiation protection standards, qualified by testing, can be used in compliance in medical/industrial scenarios

OUTUS Lead-Lined Radiation Shielding Door – 1–10mm Pb CT & DR RoomOUTUS Lead-Lined Radiation Shielding Door – 1–10mm Pb CT & DR Room
Why choose OuTus

Authentication

  • 37e065c38b4547585a484da1fa9f8507_05f76470e0be25c47b9367570f6a7298fedfae6bbcf30ef6eb8529be79782d20.png
  • b5f393b269bf5e8d51b6e89c1c528ec7_d65c8bab529ec652803e5cb9bbb8fd48c9279075a1e028d0508739ab930a9c02.png
  • c7ca8fef69012b145ed5d14d3d7e4cde_8e984a55faaca405c6dc85016fe450b41332f8326da4eb81ca7679fd4ec4133d.png
  • fe82f6e36e5d684b7ac8aefe73f581a4_e7a0f5dbc3d83b3d06500f44462cb9cd20e66a2cc24e37f5c69e826f0dcb892f.png
  • d40f02898fd60c201144619c3edae6f9_c83e84ecffe0795637634b8890d67745dcf7dae738e879364cc08e105f0c26d9.png

Technical data

Parameter Category Specification
Core Protection Material High-purity lead plate (99.99% purity)
Customizable Lead Equivalent 0.5mmPb ~ 5mmPb (for different radiation doses)
Door Frame Material Cold-rolled steel plate / 304 stainless steel / Aluminum alloy
Door Panel Surface 304 stainless steel / Anti-corrosion electrostatic spraying
Opening Mode Manual sliding / Electric sliding (optional)
Sliding Track Stainless steel silent track with wear-resistant pulleys
Sealing Performance Radiation-proof rubber sealing strips (full-circumference sealing)
Sound Insulation Performance ≥30dB (integrated soundproof structure)
Applicable Radiation Type X-ray, γ-ray, ionizing radiation (common in medical/industrial)
Max Single Door Width ≤2500mm (customizable)
Max Single Door Height ≤3000mm (customizable)
Door Panel Thickness 50mm ~ 150mm (based on lead equivalent)
Working Temperature -20℃ ~ +60℃
Protection Standard Comply with national radiation protection GB standards
Applicable Scenarios Hospital CT/DR/X-ray room, dental clinic, industrial flaw detection lab, nuclear industry computer room
Electric Version Configuration DC24V low-voltage motor, intelligent linkage interface (optional)
Surface Treatment Anti-fingerprint, anti-corrosion, easy to clean

Get a Free Quote

Our representative will contact you soon.
Email
Company Name
Mobile
Required Product
Quantity
Message
0/1000

Our Certificates

Our Certificates Our Certificates Our Certificates Our Certificates Our Certificates Our Certificates Our Certificates Our Certificates Our Certificates Our Certificates
Our Certificates
Our Certificates
Our Certificates
Our Certificates
Our Certificates
Our Certificates

Recommended Products

inquiry

Get a Free Quote

Our representative will contact you soon.
Email
Company Name
Mobile
Required Product
Quantity
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Company Name
Mobile
Required Product
Quantity
Message
0/1000